Development of a novel fluorogenic proteolytic beacon for in vivo detection and imaging of tumour-associated matrix metalloproteinase-7 activity.

The present study describes the in vivo detection and imaging of tumour-associated MMP-7 (matrix metalloproteinase-7 or matrilysin) activity using a novel polymer-based fluorogenic substrate PB-M7VIS, which serves as a selective 'proteolytic beacon' (PB) for this metalloproteinase. PB-M7VIS is built on a PAMAM (polyamido amino) dendrimer core of 14.2 kDa, covalently coupled with an Fl (fluorescein)-labelled peptide Fl(AHX)RPLALWRS(AHX)C (where AHX stands for aminohexanoic acid) and with TMR (tetramethylrhodamine). PB-M7VIS is efficiently and selectively cleaved by MMP-7 with a k (cat)/ K (m) value of 1.9x10(5) M(-1).s(-1) as measured by the rate of increase in Fl fluorescence (up to 17-fold for the cleavage of an optimized PB-M7VIS) with minimal change in the TMR fluorescence. The K (m) value for PB-M7VIS is approx. 0.5 microM, which is approx. two orders of magnitude lower when compared with that for an analogous soluble peptide, indicating efficient interaction of MMP-7 with the synthetic polymeric substrate. With MMP-2 or -3, the k (cat)/ K (m) value for PB-M7VIS is approx. 56- or 13-fold lower respectively, when compared with MMP-7. In PB-M7VIS, Fl(AHX)RPLALWRS(AHX)C is a selective optical sensor of MMP-7 activity and TMR serves to detect both the uncleaved and cleaved reagents. Each of these can be visualized as subcutaneous fluorescent phantoms in a mouse and optically discriminated based on the ratio of green/red (Fl/TMR) fluorescence. The in vivo specificity of PB-M7VIS was tested in a mouse xenograft model. Intravenous administration of PB-M7VIS gave significantly enhanced Fl fluorescence from MMP-7-positive tumours, but not from control tumours ( P <0.0001), both originally derived from SW480 human colon cancer cells. Prior systemic treatment of the tumour-bearing mice with an MMP inhibitor BB-94 ([4-( N -hydroxyamino)-2 R -isobutyl-3 S -(thienylthiomethyl)-succinyl]-L-phenylalanine- N -methylamide), markedly decreased the Fl fluorescence over the MMP-7-positive tumour by approx. 60%. Thus PB-M7VIS functions as a PB for in vivo detection of MMP-7 activity that serves to light this optical beacon and is, therefore, a selective in vivo optical molecular imaging contrast reagent.
J Oliver McIntyre, Barbara Fingleton, K Sam Wells, David W Piston, Conor C Lynch, Shiva Gautam, Lynn M Matrisian

1529 related Products with: Development of a novel fluorogenic proteolytic beacon for in vivo detection and imaging of tumour-associated matrix metalloproteinase-7 activity.

96T1 mL4/120 Packing /sleeve/bo400Tests900 tests96 assays 250 mg

Related Pathways

paperclip

#9009103   // To Up

Evaluation of fluorometric and zymographic methods as activity assays for stromelysins and gelatinases.

To measure matrix metalloproteinase (MMP) activity in a large number of samples it is advisable to use easily automated methods. We have evaluated and compared the activity of stromelysin-1 (MMP-3), matrilysin (MMP-7), 72 kDa gelatinase A (MMP-2) and 92 kDa gelatinase B (MMP-9) by zymogram analysis and fluorescent substrate degradation assays. FITC-casein and the fluorogenic peptide Dnp-Pro-beta-cyclo-hexyl-Ala-Gly-Cys(Me)-His-Ala-Lys-(N-Me-Abz)-NH 2 were used as fluorescent substrates. FITC-casein was more efficiently degraded than the fluorogenic peptide by all MMPs tested except MMP-9. MMP-2 was not significantly able to degrade the fluorogenic peptide. Gelatin zymography was the most sensitive method to detect the activity of both gelatinases but quantitation problems compromise its use. The degradation of fluorogenic substrates by MMPs could be inhibited by the chelating agent EDTA and by the tissue inhibitor of metalloproteinases 2 (TIMP-2), an MMP-specific inhibitor. Fluorometric methods represent a good alternative for MMP activity measurement, especially when a large number of samples must be processed.