Search results for: Monkey Myoglobin ELISA Kit
#33472398 2021/01/21 To Up
COMP (Cartilage Oligomeric Matrix Protein) Neoepitope: A Novel Biomarker to Identify Symptomatic Carotid Stenosis.
COMP (cartilage oligomeric matrix protein) is abundantly expressed in the cardiovascular system, cartilage, and atherosclerotic plaques. We investigated if the total COMP (COMPtotal) and COMP neoepitope (COMPneo) with other cardiovascular markers and clinical parameters could identify symptomatic carotid stenosis. Approach and Results: Blood samples were collected from patients with symptomatic carotid stenosis (stenosis, n=50), patients with stroke without carotid stenosis but small plaques (plaque, n=50), and control subjects (n=50). COMPtotal and COMPneo were measured using an ELISA. Ninety-two cardiovascular disease markers were measured by the Olink CVD kit. The presence of native COMP and COMPneo was determined by immunohistochemistry. The concentration of COMPneo was higher and COMPtotal was lower in the stenosis group. When the concentration was compared between the stenosis and control groups, IL-1ra (interleukin-1 receptor antagonist protein), IL6 (interleukin-6), REN (Renin), MMP1 (matrix metalloproteinase-1), TRAIL-R2 (tumor necrosis factor-related apoptosis-inducing ligand receptor 2), ITGB1BP2 (integrin beta 1 binding protein 2), and COMPneo were predictive of stenosis. Conversely, KLK6 (kallikrein-6), COMPtotal, NEMO (nuclear factor-kappa-B essential modulator), SRC (Proto-oncogene tyrosine-protein kinase Src), SIRT2 (SIR2-like protein), CD40 (cluster of differentiation 40), TF (tissue factor), MP (myoglobin), and RAGE (receptor for advanced glycation end-products) were predictive of the control group. Model reproducibility was good with the receiver operating characteristic plot area under the curve being 0.86. When comparing the plaque group and stenosis group, COMPneo, GAL (galanin), and PTX3 (pentraxin-related protein PTX3) were predictive of stenosis. Model reproducibility was excellent (receiver operating characteristic plot area under the curve 0.92). COMPneo was detected in smooth muscle-, endothelial-, and foam-cells in carotid stenosis.Joakim Sandstedt, Karin Vargmar, Kristina Björkman, Ulla Ruetschi, Göran Bergström, Lillemor Mattsson Hultén, Eva Skiöldebrand
2789 related Products with: COMP (Cartilage Oligomeric Matrix Protein) Neoepitope: A Novel Biomarker to Identify Symptomatic Carotid Stenosis.
2 ml96 wells (1 kit)0.1 mg0.1 mg100 100 0.5mg10 200 100Related Pathways
#26271987 // To Up
[Preparation and application of monoclonal antibody against human myoglobin].
To prepare the monoclonal antibody (mAb) against human myoglobin (MYO) of high titer and specificity and develop double-antibody sandwich ELISA for detecting MYO in human serum samples.Quanli Yang, Shiqin Liu, Siyi Tan, Chenchen Shao, Jianfang Huang, Junjian Xiang
1999 related Products with: [Preparation and application of monoclonal antibody against human myoglobin].
100ug Lyophilized25 µg25 µg100 TESTS 100ul 100ul100ug Lyophilized 100ul 100ul50ul 100ul 100ulRelated Pathways
-
No related Items
#25078431 2014/07/29 To Up
Identification of peptides that selectively bind to myoglobin by biopanning of phage displayed-peptide library.
Biopanning of phage displayed-peptide library was performed against myoglobin, a marker for the early assessment of acute myocardial infarction (AMI), to identify peptides that selectively bind to myoglobin. Using myoglobin-conjugated magnetic beads, phages that bound to myoglobin were collected and amplified for the next round of screening. A 148-fold enrichment of phage titer was observed after five rounds of screening relative to the first round. After phage binding ELISA, three phage clones were selected (3R1, 3R7 and 3R10) and the inserted peptides were chemically synthesized. The analysis of binding affinity showed that the 3R7 (CPSTLGASC) peptide had higher binding affinity (Kd=57 nM) than did the 3R1 (CNLSSSWIC) and 3R10 (CVPRLSAPC) peptide (Kd=125 nM and 293 nM, respectively). Cross binding activity to other proteins, such as bovine serum albumin, troponin I, and creatine kinase-MB, was minimal. In a peptide-antibody sandwich ELISA, the selected peptides efficiently captured myoglobin. Moreover, the concentrations of myoglobin in serum samples measured by a peptide-peptide sandwich assay were comparable to those measured by a commercial antibody-based kit. These results indicate that the identified peptides can be used for the detection of myoglobin and may be a cost effective alternative to antibodies.Guruprasath Padmanaban, Hyekyung Park, Ji Suk Choi, Yong-Woo Cho, Woong Chol Kang, Chan-Il Moon, In-San Kim, Byung-Heon Lee
1683 related Products with: Identification of peptides that selectively bind to myoglobin by biopanning of phage displayed-peptide library.
5 G100 mg 1 mg 100 mg1 g0.1 mg96T25.0 mg5 g25 g50 25 gRelated Pathways
#22652544 // To Up
Serum angiopoietin-like protein 3 concentrations in rheumatic diseases.
Angiopoietin-like protein 3 (Angptl3) is one of the angiogenic cytokines that stimulates endothelial cell adhesion, migration, and neovascularization. No link has been established between Angptl3 and rheumatic diseases such as systemic sclerosis or dermatomyositis (DM). In this study, we determined the serum Angptl3 levels in patients with various rheumatic diseases, and tried to evaluate the possibility that serum levels of Angptl3 can be a useful disease marker. Serum samples were collected from 21 SSc patients, 10 systemic lupus erythematosus (SLE) patients, 21 DM patients, 5 polymyositis (PM) patients and 11 patients with clinically amyopathic DM (CADM) as well as 12 healthy volunteers. Levels of serum Angptl3 were measured with a specific ELISA kit. There was a significant increase of serum Angptl3 levels in patients with SSc or DM (p<0.05). Levels of serum Angptl3 were also slightly higher in patients with ADM, PM or SLE compared with healthy controls, but not statistically significant. Myoglobin levels were significantly higher in DM patients with increased serum Angptl3 levels than those with normal levels (p<0.05). In addition, among patients with SSc, the prevalence of cutaneous ulcers was significantly greater in patients with elevated Angptl3 levels than those with normal levels (p<0.05). Serum Angptl3 levels may be associated with the pathogenesis of muscle involvement in DM patients and microangiopathy in SSc patients. Clarifying the role of Angptl3 in each rheumatic disease may lead to further understanding of the pathogenesis and new therapeutic approaches.Yasuyo Hayashi, Masatoshi Jinnin, Takamitsu Makino, Ikko Kajihara, Katsunari Makino, Noritoshi Honda, Wakana Nakayama, Kuniko Inoue, Satoshi Fukushima, Hironobu Ihn
1246 related Products with: Serum angiopoietin-like protein 3 concentrations in rheumatic diseases.
20096T180 Tests / Kit1 Set1 Set1 Set500 ml10ml1 Set1 Set1 Set1 SetRelated Pathways
#10905760 // To Up
Human heart-type cytoplasmic fatty acid-binding protein (H-FABP) for the diagnosis of acute myocardial infarction. Clinical evaluation of H-FABP in comparison with myoglobin and creatine kinase isoenzyme MB.
Heart-type fatty acid-binding protein (H-FABP) is a low molecular weight cytoplasmic protein and present abundantly in the myocardium. When the myocardium is injured, as in the case of myocardial infarction, low molecular weight cytoplasmic proteins including H-FABP are released into the circulation and H-FABP is detectable in a blood sample. We have already developed a direct sandwich-ELISA for quantification of human H-FABP using two distinct types of monoclonal antibodies specific for human H-FABP. In this study we investigated the clinical validity of H-FABP as a biochemical diagnostic marker in the early phase of acute myocardial infarction (AMI). To evaluate the diagnostic usefulness of H-FABP in the early phase of AMI, blood samples were obtained from the following patients within 12 hours after the appearance of symptoms, and serum levels of H-FABP were compared with those of conventional diagnostic markers, such as myoglobin and creatine kinase isoenzyme MB (CK-MB). Blood samples were collected from patients with confirmed AMI (n=140), patients with chest pain who were afterwards not classified as AMI by normal CK-MB levels (non-AMI) (n=49) and normal healthy volunteers (n=75). The serum concentration of H-FABP was quantified with our direct sandwich-ELISA. The concentration of myoglobin mass was measured with a commercial RIA kit. The serum CK-MB activity was determined with an immuno-inhibition assay kit. The overall sensitivity of H-FABP, within 12 hours after the appearance of symptoms, was 92.9%, while it was 88.6% with myoglobin and 18.6% with CK-MB. The overall specificity of H-FABP was 67.3%, while it was 57.1% with myoglobin and 98.0% with CK-MB. The diagnostic efficacy rates with these markers were 86.2% (H-FABP), 80.4% (myoglobin) and 39.2% (CK-MB), respectively. The diagnostic validity of H-FABP was further assessed by receiver operating characteristic (ROC) curve analysis. The area under the curve (AUC) of H-FABP was 0.921, which was significantly greater than with myoglobin (AUC: 0.843) and CK-MB (AUC: 0.654). These parameters, such as sensitivity, specificity, diagnostic efficacy and diagnostic accuracy, obtained for patients with chest pain within 3 hours and/or 6 hours after the onset of symptoms were almost the same as those for patients within 12 hours after symptoms. H-FABP is more sensitive than both myoglobin and CK-MB, more specific than myoglobin for detecting AMI within 12 hours after the onset of symptoms, and shows the highest values for both diagnostic efficacy and ROC curve analysis. Thus, H-FABP has great potential as an excellent biochemical cardiac marker for the diagnosis of AMI in the early phase.F Okamoto, K Sohmiya, Y Ohkaru, K Kawamura, K Asayama, H Kimura, S Nishimura, H Ishii, N Sunahara, T Tanaka
1895 related Products with: Human heart-type cytoplasmic fatty acid-binding protein (H-FABP) for the diagnosis of acute myocardial infarction. Clinical evaluation of H-FABP in comparison with myoglobin and creatine kinase isoenzyme MB.
1 mg96tests100ug Lyophilized0.1 mg250.1 mg100 μg0.1 mg100 μg100.1 mg 100 UGRelated Pathways
#9613705 // To Up
Influence of some factors on immunoassays of human myoglobin.
Six ELISA variants exploiting two monoclonal antibodies, one rabbit antibody and their peroxidase conjugates were applied in assays of purified human myoglobin, apomyoglobin and the protein in human muscle extracts. The myoglobin was accurately determined with monoclonal antibody no. 82 used for coating of ELISA plates while assays performed with monoclonal antibody no. 49 or rabbit antibody used for coating were weak or none. Determinations of human apomyoglobin with ELISA variants were somewhat more sensitive than those of myoglobin. Obtained in this work results were compared with those done using commercial Seratec kit for immunoassay of human myoglobin. Addition to the muscle extracts not only concentrated salts but also acetone, ethanol, sodium dodecyl sulfate or some other denaturing agents markedly increased assays of myoglobin by ELISA with monoclonal antibody no. 49 and antibody no. 82 conjugated with peroxidase. Removal of acetone or ammonium sulfate from extracts resulted in dramatic decrease of the estimated myoglobin. Filtration of the extract through Bio-Gel A5m column did not affect low assays of myoglobin in fractions without pretreatment with acetone. Myoglobin was isolated from human heart extract by immunoaffinity chromatography on Sepharose-antibody no. 82 column and the isolated protein was identified by gel electrophoresis and Western blot.I E Kochanowska, M Kuropatwa, A Szewczuk
2619 related Products with: Influence of some factors on immunoassays of human myoglobin.
1mg10 mg16 Arrays/Slide0.25 mg1 mg100 0.1mg200 100 units1 mg16 Arrays/Slide10 μgRelated Pathways
#7685040 // To Up
The use of T bag synthesis with paper discs as the solid phase in epitope mapping studies.
Epitope mapping with synthetic peptides bound to derivatized paper discs has been investigated using the discs both as a solid-phase matrix for peptide synthesis as well as the solid phase in immunologic testing procedures without detachment of the peptides from the paper discs. Using the T bag (tea bag) method the simultaneous synthesis and subsequent immunologic testing of large numbers of peptides was demonstrated for the feline major allergen Fel d I. A total of 15,000 paper disc-bound peptides, comprising the 146 nonapeptides overlapping by eight amino acid residues on both chains, were synthesized simultaneously with 100 paper discs per T bag. Using these paper disc-bound peptides as the solid phase in radioimmunoassays the binding sites found coincided with those detected in the PEPSCAN with the commercially available epitope mapping kit and with the binding sites that had been found with Sepharose-coupled peptides. The signal to background-ratio in the paper disc-RIA was comparable to that in the PEPSCAN and the reproducibility was good. The bound antibodies could be eluted from the paper disc-bound peptides, permitting regeneration and repeated use of the paper discs for immunologic testing. This method was shown to be a useful alternative to the PEPSCAN and to have the major advantage that large numbers of antibodies could be tested with large numbers of peptides simultaneously.W van 't Hof, M van den Berg, R C Aalberse
2195 related Products with: The use of T bag synthesis with paper discs as the solid phase in epitope mapping studies.
10.1ml (1mg/ml)Related Pathways
#1810699 // To Up
Enzyme immunoassay to determine serum myoglobin in patients with acute myocardial infarction.
A method of "sandwich" enzyme immunoassay was developed for determination of human serum myoglobin with the use of myoglobin isolated from human myocardium and gammaglobulin fraction of a specific sheep antiserum labelled with horseradish peroxidase. The linear part of the calibration curve within the range of 0.08-2.2 nmol/l is suitable for accurate quantitative reading of myoglobin concentration. Intra- and interassay variation coefficients are 7% and 11.2%, respectively. A comparison of 100 serum samples assessed by means of commercially available RIA kit and by the given method revealed a correlation coefficient of 0.86.I Kurcová, H Tlaskalová, M Srámek, J Bouzek, P Mancal, I Malbohan
1935 related Products with: Enzyme immunoassay to determine serum myoglobin in patients with acute myocardial infarction.
1 kit96 rxns50 ml96 wells (1 kit)1x96 well plate500 ml5ml1x96 well plate10 mlRelated Pathways
Contact Us:
Belgium
Voortstraat 49, 1910 Kampenhout BELGIUM
Tel 0032 16 58 90 45 Fax 0032 16 50 90 45
[email protected]
France
9, rue Lagrange, 75005 Paris
Tel 01 43 25 01 50 Fax 01 43 25 01 60
[email protected]
Germany
GENTAUR GmbH
Marienbongard 20
52062 Aachen Deutschland
Tel 0241 40 08 90 86 Fax 0241 55 91 05 36
[email protected]
United Kingdom
GENTAUR Ltd.
Howard Frank Turnberry House
1404-1410 High Road
Whetstone London N20 9BH
Tel 020 3393 8531 Fax 020 8445 9411
[email protected]
Also in
Luxembourg +35220880274
Schweiz Züri +41435006251
Danmark +4569918806
Österreich +43720880899
Česká republika Praha +420246019719
Ireland Dublin +35316526556
Norge Oslo +4721031366
Finland Helsset +358942419041
Sverige Stockholm +46852503438
Ελλάς Αθήνα +302111768494
Magyarország Budapest +3619980547
Poland
GENTAUR Poland Sp. z o.o.
ul. Grunwaldzka 88/A m.2
81-771 Sopot, Poland
Tel 058 710 33 44
Fax 058 710 33 48
[email protected]
skype gentaurpoland
Nederland
GENTAUR Nederland BV
Kuiper 1
5521 DG Eersel Nederland
Tel 0208-080893 Fax 0497-517897
[email protected]
Italy
GENTAUR SRL
IVA IT03841300167
Piazza Giacomo Matteotti, 6, 24122 Bergamo
Tel 02 36 00 65 93 Fax 02 36 00 65 94
[email protected]
Spain
GENTAUR Spain
Tel 0911876558
[email protected]
Bulgaria
GENTAUR Bulgaria
53 Iskar Str. 1191 Kokalyane, Sofia
Sofia 1000
Tel 0035924682280
Fax 0035929830072
[email protected]