Search results for: Mouse Anti-Human Pro-BNP Antibodies
#35608240 2022/06/09 To Up
A rapid and quantitative detection method for plasma soluble growth stimulating gene protein 2 based on time resolved fluorescence immunochromatography.
: plasma soluble growth stimulating gene protein 2 (sST2) is a new generation biomarker in heart failure (HF), which is an independent predictor of adverse outcomes of heart failure. Thus, the establishment of a rapid and sensitive method for detecting sST2 is urgently needed. : lanthanide element Eu coated fluorescent nanometer microspheres (Eu@FMN) can be used as markers to label monoclonal mouse anti-human sST2 antibody ST-01 (ST-01-Eu@FMN). When the immune sandwich complex formed between the monoclonal mouse anti-human sST2 antibody ST-02 and ST-01-Eu@FMN on the test band with the appearance of target object sST2, we can detect the fluorescence intensity of Eu on the test band and the quality control band using a dry fluorescence analyzer. We calculated the / value (/ = fluorescence intensity of the test band/fluorescence intensity of the quality control band), fitted to the calibration curve, and measured the concentration value of sST2 in the corresponding sample. : the best reaction time was 15 min after condition exploration, and the optimal sample volume was 80 μL. The detection sensitivity of the scheme was 2.14 ng mL. The calibration curve of the assay was = 0.0113 + 0.0033, and the linear range was 5-200 ng mL. No cross reaction was found when the samples contained BNP, NT-proBNP, and galectin-3, indicating a good specificity. The precision was good with a relative deviation < 15%. The coefficient of variation of detection results of low-concentration samples and high-concentration samples was 4.20% and 3.30% respectively in the same batch of strip tests, so the intra-assay CV was set as <10%; when different batches of strips were used for testing, the coefficient of variation of detection results of low-concentration samples and high-concentration samples was 10.06% and 8.38% respectively, so the inter-assay CV was set as <15%. Stability test results showed that the relative deviation of test results at each time node was <15%, indicating good stability of the assay strips. The correlation coefficient between the ST-01-Eu@FMN based time-resolved fluorescence immunochromatography analysis and sST2 ELISA kit was 0.98. To confirm the usage of our proposed TRF-ICA for clinical samples, it was used to determine the concentration of sST2 in samples obtained from 34 patients with heart insufficiency, acute and chronic heart failure. As a result, we successfully detected a minimal concentration of 5.21 ng mL and a maximum concentration of 184.26 ng mL for sST2. : this technique provides a rapid, simple and quantitative detection method for sST2 in clinics. It can help clinicians to predict the incidence of adverse events in patients with HF.Xiaoying Jing, Shanchao Hong, Jian Zhang, Xue Yang, Xianlong Geng, Yan Ye, Zhigang Hu
1812 related Products with: A rapid and quantitative detection method for plasma soluble growth stimulating gene protein 2 based on time resolved fluorescence immunochromatography.
250tests100tests100tests200ul100tests100Tests100tests100tests100tests250TestsRelated Pathways
Contact Us:
Belgium
Voortstraat 49, 1910 Kampenhout BELGIUM
Tel 0032 16 58 90 45 Fax 0032 16 50 90 45
[email protected]
France
9, rue Lagrange, 75005 Paris
Tel 01 43 25 01 50 Fax 01 43 25 01 60
[email protected]
Germany
GENTAUR GmbH
Marienbongard 20
52062 Aachen Deutschland
Tel 0241 40 08 90 86 Fax 0241 55 91 05 36
[email protected]
United Kingdom
GENTAUR Ltd.
Howard Frank Turnberry House
1404-1410 High Road
Whetstone London N20 9BH
Tel 020 3393 8531 Fax 020 8445 9411
[email protected]
Also in
Luxembourg +35220880274
Schweiz Züri +41435006251
Danmark +4569918806
Österreich +43720880899
Česká republika Praha +420246019719
Ireland Dublin +35316526556
Norge Oslo +4721031366
Finland Helsset +358942419041
Sverige Stockholm +46852503438
Ελλάς Αθήνα +302111768494
Magyarország Budapest +3619980547
Poland
GENTAUR Poland Sp. z o.o.
ul. Grunwaldzka 88/A m.2
81-771 Sopot, Poland
Tel 058 710 33 44
Fax 058 710 33 48
[email protected]
skype gentaurpoland
Nederland
GENTAUR Nederland BV
Kuiper 1
5521 DG Eersel Nederland
Tel 0208-080893 Fax 0497-517897
[email protected]
Italy
GENTAUR SRL
IVA IT03841300167
Piazza Giacomo Matteotti, 6, 24122 Bergamo
Tel 02 36 00 65 93 Fax 02 36 00 65 94
[email protected]
Spain
GENTAUR Spain
Tel 0911876558
[email protected]
Bulgaria
GENTAUR Bulgaria
53 Iskar Str. 1191 Kokalyane, Sofia
Sofia 1000
Tel 0035924682280
Fax 0035929830072
[email protected]