Search results for: Near-Infrared Spectroscopy (NIRS) of Muscle HbO and MbO Desaturation During Exercise.
#33966199 // To Up
Near-Infrared Spectroscopy (NIRS) of Muscle HbO and MbO Desaturation During Exercise.
Continuous noninvasive monitoring of muscle oxygenation has important clinical applications for muscle disorders such as compartmentation syndrome, fibromyalgia, deep vein thrombosis, malignant hyperthermia, and the assessment of training in athletic performance. NIRS has precisely such potential and has been used to detect deep venous thrombosis, evaluate athletic performance, and assess limb reperfusion and revascularization. The aim of this study was to examine the relationship between muscle hemoglobin oxygen (HbO) and myoglobin (MbO) desaturation using NIRS combined with venous blood sampling and HbO desaturation during forearm muscle exercise. Eleven normal subjects were studied, with informed consent and an IRB-approved protocol. A NIRS sensor (INVOS4100, Somanetics, Corp.) was applied on the volar aspect of the forearm. The subjects exercised their forearm by clenching and relaxing their fist while observing the oximeter and driving the reading to specified levels from 90% to 15% (minimum possible reading). Venous blood samples were withdrawn for measurement of blood gases and oxygen saturation (IL-Co-Oximeter). RSO (%) vs VO Sat showed a two-component HbO desaturation suggesting representation of venous HbO desaturation and perhaps myoglobin oxygen (MBO) desaturation. Subtraction of the linear venous HbO curve from the two-component curve suggests MbO desaturation at venous hemoglobin oxygen saturation of about 10-20%. Conclusions: The kinetics of desaturation during exercise revealed two components representing HbO and MbO deoxygenation. The data show that MbO represents approximately 40% of the NIRS signal and the balance or 60% to HbO.Edwin M Nemoto
1857 related Products with: Near-Infrared Spectroscopy (NIRS) of Muscle HbO and MbO Desaturation During Exercise.
100ug100ul 6 ml Ready-to-use 100 mg100ul1 mg1000 tests200ul6 mL0.5 ml500 MG100ugRelated Pathways
Contact Us:
Belgium
Voortstraat 49, 1910 Kampenhout BELGIUM
Tel 0032 16 58 90 45 Fax 0032 16 50 90 45
[email protected]
France
9, rue Lagrange, 75005 Paris
Tel 01 43 25 01 50 Fax 01 43 25 01 60
[email protected]
Germany
GENTAUR GmbH
Marienbongard 20
52062 Aachen Deutschland
Tel 0241 40 08 90 86 Fax 0241 55 91 05 36
[email protected]
United Kingdom
GENTAUR Ltd.
Howard Frank Turnberry House
1404-1410 High Road
Whetstone London N20 9BH
Tel 020 3393 8531 Fax 020 8445 9411
[email protected]
Also in
Luxembourg +35220880274
Schweiz Züri +41435006251
Danmark +4569918806
Österreich +43720880899
Česká republika Praha +420246019719
Ireland Dublin +35316526556
Norge Oslo +4721031366
Finland Helsset +358942419041
Sverige Stockholm +46852503438
Ελλάς Αθήνα +302111768494
Magyarország Budapest +3619980547
Poland
GENTAUR Poland Sp. z o.o.
ul. Grunwaldzka 88/A m.2
81-771 Sopot, Poland
Tel 058 710 33 44
Fax 058 710 33 48
[email protected]
skype gentaurpoland
Nederland
GENTAUR Nederland BV
Kuiper 1
5521 DG Eersel Nederland
Tel 0208-080893 Fax 0497-517897
[email protected]
Italy
GENTAUR SRL
IVA IT03841300167
Piazza Giacomo Matteotti, 6, 24122 Bergamo
Tel 02 36 00 65 93 Fax 02 36 00 65 94
[email protected]
Spain
GENTAUR Spain
Tel 0911876558
[email protected]
Bulgaria
GENTAUR Bulgaria
53 Iskar Str. 1191 Kokalyane, Sofia
Sofia 1000
Tel 0035924682280
Fax 0035929830072
[email protected]