Search results for: Plasma neutrophil gelatinase-associated lipocalin and Interleukin-18 as predictors of acute kidney injury in renal transplant recipients: A pilot study.
#35017329 // To Up
Plasma neutrophil gelatinase-associated lipocalin and Interleukin-18 as predictors of acute kidney injury in renal transplant recipients: A pilot study.
Urine neutrophil gelatinase-associated lipocalin (NGAL) and interleukin-18 (IL- 18) have shown promise for predicting renal graft recovery. However, urinary flow rate variations may cause variable biomarker dilution. Plasma NGAL and IL-18 may form a biomarker panel that may help predict delayed graft function and slow graft function (SGF) in renal transplant recipients within the first two postoperative days earlier than serum creatinine. There are only a few studies in the literature using plasma NGAL for predicting renal graft recovery. Hence, we planned this study. This observational single-center, prospective cohort study was conducted in renal transplant recipients above 18 years of age. In 22 consecutive renal transplant recipients, we collected ethylenediaminetetraacetic acid-plasma samples 1 h before surgery and subsequently at 6 h, 24 h, and 48 h after surgery for NGAL and IL-18 by sandwich enzyme-linked immuno-sorbent assay technique. Serum creatinine was measured as a part of routine transplant protocol. In renal transplant recipients, neither serum levels of NGAL and IL-18 nor their trends could reliably predict SGF. The only significant correlation existed between serum creatinine at day 2 and IL-18 at day 2 with P = 0.023. Serum NGAL did not correlate with serum creatinine in this setting of renal transplantation. Patients with immediate graft function had a greater percentage decrease of creatinine at day 1 and day 2 (P = 0.002 and 0.001) The percentage change in IL-18 at 24 h and 48 h after transplant from baseline could predict the occurrence of early graft loss (EGL) (P = 0.05, 0.04). The cutoffs were -4.12% at day 1 and +3.39% at day 2 with area under receiver operator characteristics of 0.82 and 0.83, respectively. The percentage change in IL-18 may be a useful marker of EGL in renal transplant recipients. Serum NGAL and creatinine were not able to predict EGL.Karthik T Ponnappan, Mohd Qurram Parveez, Chandra Kant Pandey, Ankur Sharma, Manish Tandon, Vikas Jain, Vijay Kant Pandey, Sherin Thomas
2125 related Products with: Plasma neutrophil gelatinase-associated lipocalin and Interleukin-18 as predictors of acute kidney injury in renal transplant recipients: A pilot study.
100 assays96T100.00 ug0.1ml (1mg/ml) 100ul100.00 ug1 mg 0.1 mg 32-50 Sample KitRelated Pathways
Contact Us:
Belgium
Voortstraat 49, 1910 Kampenhout BELGIUM
Tel 0032 16 58 90 45 Fax 0032 16 50 90 45
[email protected]
France
9, rue Lagrange, 75005 Paris
Tel 01 43 25 01 50 Fax 01 43 25 01 60
[email protected]
Germany
GENTAUR GmbH
Marienbongard 20
52062 Aachen Deutschland
Tel 0241 40 08 90 86 Fax 0241 55 91 05 36
[email protected]
United Kingdom
GENTAUR Ltd.
Howard Frank Turnberry House
1404-1410 High Road
Whetstone London N20 9BH
Tel 020 3393 8531 Fax 020 8445 9411
[email protected]
Also in
Luxembourg +35220880274
Schweiz Züri +41435006251
Danmark +4569918806
Österreich +43720880899
Česká republika Praha +420246019719
Ireland Dublin +35316526556
Norge Oslo +4721031366
Finland Helsset +358942419041
Sverige Stockholm +46852503438
Ελλάς Αθήνα +302111768494
Magyarország Budapest +3619980547
Poland
GENTAUR Poland Sp. z o.o.
ul. Grunwaldzka 88/A m.2
81-771 Sopot, Poland
Tel 058 710 33 44
Fax 058 710 33 48
[email protected]
skype gentaurpoland
Nederland
GENTAUR Nederland BV
Kuiper 1
5521 DG Eersel Nederland
Tel 0208-080893 Fax 0497-517897
[email protected]
Italy
GENTAUR SRL
IVA IT03841300167
Piazza Giacomo Matteotti, 6, 24122 Bergamo
Tel 02 36 00 65 93 Fax 02 36 00 65 94
[email protected]
Spain
GENTAUR Spain
Tel 0911876558
[email protected]
Bulgaria
GENTAUR Bulgaria
53 Iskar Str. 1191 Kokalyane, Sofia
Sofia 1000
Tel 0035924682280
Fax 0035929830072
[email protected]