Only in Titles

Search results for: Rabbit Anti-ACE2 Polyclonal Antibody, PE-Cy5.5 conjugated Isotype: IgG

paperclip

#32762697   2020/08/06 To Up

Evaluation of an in-house indirect enzyme-linked immunosorbent assay of feline panleukopenia VP2 subunit antigen in comparison to hemagglutination inhibition assay to monitor tiger antibody levels by Bayesian approach.

Feline panleukopenia virus (FPV) is an etiologic pathogen of feline panleukopenia that infects all members of Felidae including tigers (Panthera tigris). Vaccinations against FPV among wild felid species have long been practiced in zoos worldwide. However, few studies have assessed the tiger immune response post-vaccination due to the absence of a serological diagnostic tool. To address these limitations, this study aimed to develop an in-house indirect enzyme-linked immunosorbent assay (ELISA) for the monitoring of tiger antibody levels against the feline panleukopenia vaccine by employing the synthesized subunit capsid protein VP2. An in-house horseradish peroxidase (HRP) conjugated rabbit anti-tiger immunoglobulin G (IgG) polyclonal antibody (HRP-anti-tiger IgG) was produced in this study and employed in the assay. It was then compared to a commercial HRP-conjugated goat anti-cat IgG (HRP-anti-cat IgG). Sensitivity and specificity were evaluated using the Bayesian model with preferential conditional dependence between HRP-conjugated antibody-based ELISAs and hemagglutination-inhibition (HI) tests.
Chanakan Areewong, Amarin Rittipornlertrak, Boondarika Nambooppha, Itsarapan Fhaikrue, Tawatchai Singhla, Chollada Sodarat, Worapat Prachasilchai, Preeyanat Vongchan, Nattawooti Sthitmatee

2250 related Products with: Evaluation of an in-house indirect enzyme-linked immunosorbent assay of feline panleukopenia VP2 subunit antigen in comparison to hemagglutination inhibition assay to monitor tiger antibody levels by Bayesian approach.

1 kit(96 Wells)1 kit(96 Wells)1 kit(96 Wells)1 kit(96 Wells)1 kit(96 Wells)1 kit(96 Wells)1 kit(96 Wells)1 kit(96 Wells)1 kit(96 Wells)1 kit(96 Wells)1 kit(96 Wells)1 kit(96 Wells)

Related Pathways

paperclip

#32663533   2020/07/11 To Up

A rapid and sensitive lateral flow immunoassay (LFIA) test for the on-site detection of banana bract mosaic virus in banana plants.

Banana bract mosaic virus (BBrMV) is a serious pathogen threatening the cultivation of banana and plantain worldwide. This study reports the development of a practical, rapid, sensitive, specific and user-friendly lateral flow immunoassay (LFIA) test for the on-site detection of BBrMV. The BBrMV coat protein (CP) was expressed in Escherichia coli and purified and used to immunize rabbits to produce a polyclonal antiserum (anti-BBrMVCP). The test was based on a double-antibody sandwich format. Protein-A affinity column-purified anti-BBrMVCP Immunoglobulins (IgG) (16 μg/mL), conjugated to ∼30 nm gold nanoparticles, was applied onto the conjugate pad. The anti-BBrMVCP IgG and goat anti-rabbit IgG were printed on the surface of a nitrocellulose filter membrane as the test line and control line, respectively. A positive result could be confirmed visually by the presence of a pink band that developed on the LFIA strip within 5-10 min. The detection limit of the test was 10 ng of the expressed recombinant BBrMV CP (rBBrMVCP), and a 1:20 dilution of the BBrMV-infected crude extract. This LFIA test was validated using 114 banana leaf samples randomly collected from the field and the results indicated a very high diagnostic sensitivity (99.04 %) and specificity (100 %) for the test. A Cohen's kappa coefficient of 0.861 obtained also indicated a very good agreement between the LFIA developed in this study and ELISA. This assay could be adopted by farmers, tissue culture industries and quarantine departments for surveys and surveillance. This is the first report on the development of a LFIA-based test for BBrMV detection.
Ramasamy Selvarajan, Prasanya Selvam Kanichelvam, Velusamy Balasubramanian, Sundaram Sethurama Subramanian

1913 related Products with: A rapid and sensitive lateral flow immunoassay (LFIA) test for the on-site detection of banana bract mosaic virus in banana plants.

96 tests100tests1 kit1 mg1000 tests1 mL 96 Tests

Related Pathways

paperclip

#32199081   2020/02/24 To Up

Early diagnosis of experimental Trichinella spiralis infection by nano-based enzyme-linked immunosorbent assay (nano-based ELISA).

T
, , , ,

2449 related Products with: Early diagnosis of experimental Trichinella spiralis infection by nano-based enzyme-linked immunosorbent assay (nano-based ELISA).

One 96-Well Microplate KiTwo 96-Well Microplate KiOne 96-Well Microplate KiOne 96-Well Microplate KiOne 96-Well Microplate Ki500 testsOne 96-Well Microplate KiOne 96-Well Microplate KiTwo 96-Well Microplate KiOne 96-Well Microplate KiOne 96-Well Microplate Ki

Related Pathways

    No related Items
paperclip

#29689714   // To Up

Production and characterization of anti-human IgG F(ab')2 antibody fragment.

In present study an optimized protocol for the separation of antibodies into antigen-binding fragments F(ab')2 using pepsin digestion was investigated. The production of these fragments is a consequential step in the development of medical research, treatment and diagnosis. For production of polyclonal antibody rabbit received antigen in four steps. The rabbit serum at 1/128000 dilution showed high absorbance in reaction with human IgG at the designed ELISA method. Rabbit IgG was purified by Ion-Exchange Chromatography (IEC) method. Purity was assessed by SDS-PAGE method. In non-reduced condition only one band was seen in about 150 kDa MW position and in reduced form, two bands were seen in 50 and 25 kDa MW positions. Rabbit IgG was digested by pepsin enzyme. The antibody fragments solution was applied to Gel filtration column to isolate the F(ab')2. Non-reduced SDS-PAGE for determining the purity of F(ab')2 fragment resulted in one band in 100 kDa corresponds to F(ab')2 fragment and a band in 150 kDa MW position corresponds to undigested IgG antibodies. The activities of FITC conjugated F(ab')2 fragment and commercial ones were compared using flowcytometry method. The activity results implied that the FITC conjugated- anti human F(ab')2 fragment worked as efficiently as the commercial one.
Zahra Valedkarimi, Hadi Nasiri, Leili Aghebati-Maleki, Jalal Abdolalizadeh, Mojghan Esparvarinha, Jafar Majidi

1650 related Products with: Production and characterization of anti-human IgG F(ab')2 antibody fragment.