Only in Titles

Search results for: Rabbit Anti-FGF4 Polyclonal Antibody, Gold Conjugated

paperclip

#33527460   2021/02/01 To Up

Development and evaluation of colloidal gold immunochromatography test strip for rapid diagnosis of nervous necrosis virus in golden grey mullet (Chelon aurata).

A lateral flow immunochromatography strip test, based on antibody-gold nanoparticles specific for nervous necrosis virus (NNV), was developed for rapid, on-site detection of the virus in fish stocks. A monoclonal antibody against NNV was conjugated with colloidal gold as the detector antibody. A rabbit anti-NNV polyclonal antibody and goat anti-mouse IgG antibody were blotted onto the nitrocellulose membrane as the capture antibodies on the test line and control line, respectively. The reaction could be seen by the eye within 15 min and did not cross-react with the other viruses tested. The detection limit of the strip was approximately 10 TCID /ml and had good stability after storage at 4°C for 8 months. When brains of 70 naturally infected golden grey mullet, Chelon aurata, were tested with the strip test, the diagnostic specificity and sensitivity of the test compared to real-time RT-PCR were 100% and 74%, respectively. Therefore, the one-step test strip developed here had high specificity, reproducibility, and stability. This, together with its simplicity to use and rapid detection, without the requirement of sophisticated equipment or specialized skills, makes the strip suitable for pond-side detection of NNV in farmed fish.
Fatemeh Hassantabar, Mohammad J Zorriehzahra, Farid Firouzbakhsh, Kim D Thompson

2243 related Products with: Development and evaluation of colloidal gold immunochromatography test strip for rapid diagnosis of nervous necrosis virus in golden grey mullet (Chelon aurata).

20 ul10050 ul500 tests500 tests20 ul20 ul50 ul10020 ul500 tests50 ul

Related Pathways

paperclip

#32930214   // To Up

A one-step potentiometric immunoassay for plasma cardiac troponin I using an antibody-functionalized bis-MPA-COOH dendrimer as a competitor with improved sensitivity.

Herein, we have reported a new one-step potentiometric immunoassay for the sensitive and specific detection of human plasma cardiac troponin I (cTnI), a biomarker of cardio-cerebrovascular diseases. Initially, the cTnI biomolecules were immobilized on the surface of a gold nanoparticle-functionalized screen-printed graphite electrode (SPGE). Thereafter, rabbit polyclonal antibodies to cTnI were covalently conjugated to the bis-MPA-COOH dendrimers through typical carbodiimide coupling. The introduction of the target analyte caused a competitive immunoreaction between the immobilized cTnI on the electrode and the conjugated antibody on the dendrimers. The potentiometric measurement was mainly derived from the change in the surface charge on the surface of the modified electrode due to the negatively charged bis-MPA-COOH dendrimers after the immunoreaction. On increasing target cTcI, the number of charged dendrimers on the immunosensor decreased, resulting in a change in the electric potential. Under optimum conditions, the potentiometric immunosensor exhibited good potentiometric responses for the detection of cTcI and allowed the determination of the target analyte at a concentration as low as 7.3 pg mL-1. An intermediate precision of ≤8.7% was accomplished with batch-to-batch identification. Meanwhile, the potentiometric immunosensor showed good anti-interfering capacity and selectivity against other proteins and biomarkers. Importantly, our system displayed high accuracy for the analysis of human plasma serum samples containing target cTcI relative to commercial human cTcI enzyme-linked immunosorbent assay (ELISA) kits.
Erru Ni, Yizhen Fang, Fangfang Ma, Gaoshun Ge, Jingyi Wu, Yingying Wang, Yao Lin, Huabin Xie

1015 related Products with: A one-step potentiometric immunoassay for plasma cardiac troponin I using an antibody-functionalized bis-MPA-COOH dendrimer as a competitor with improved sensitivity.

100ug Lyophilized100ug Lyophilized100ug Lyophilized100ug Lyophilized100ug Lyophilized100ug Lyophilized100ug Lyophilized100ug Lyophilized100ug Lyophilized1 kit100ug Lyophilized100ug Lyophilized

Related Pathways

paperclip

#32663533   2020/07/11 To Up

A rapid and sensitive lateral flow immunoassay (LFIA) test for the on-site detection of banana bract mosaic virus in banana plants.

Banana bract mosaic virus (BBrMV) is a serious pathogen threatening the cultivation of banana and plantain worldwide. This study reports the development of a practical, rapid, sensitive, specific and user-friendly lateral flow immunoassay (LFIA) test for the on-site detection of BBrMV. The BBrMV coat protein (CP) was expressed in Escherichia coli and purified and used to immunize rabbits to produce a polyclonal antiserum (anti-BBrMVCP). The test was based on a double-antibody sandwich format. Protein-A affinity column-purified anti-BBrMVCP Immunoglobulins (IgG) (16 μg/mL), conjugated to ∼30 nm gold nanoparticles, was applied onto the conjugate pad. The anti-BBrMVCP IgG and goat anti-rabbit IgG were printed on the surface of a nitrocellulose filter membrane as the test line and control line, respectively. A positive result could be confirmed visually by the presence of a pink band that developed on the LFIA strip within 5-10 min. The detection limit of the test was 10 ng of the expressed recombinant BBrMV CP (rBBrMVCP), and a 1:20 dilution of the BBrMV-infected crude extract. This LFIA test was validated using 114 banana leaf samples randomly collected from the field and the results indicated a very high diagnostic sensitivity (99.04 %) and specificity (100 %) for the test. A Cohen's kappa coefficient of 0.861 obtained also indicated a very good agreement between the LFIA developed in this study and ELISA. This assay could be adopted by farmers, tissue culture industries and quarantine departments for surveys and surveillance. This is the first report on the development of a LFIA-based test for BBrMV detection.
Ramasamy Selvarajan, Prasanya Selvam Kanichelvam, Velusamy Balasubramanian, Sundaram Sethurama Subramanian

2476 related Products with: A rapid and sensitive lateral flow immunoassay (LFIA) test for the on-site detection of banana bract mosaic virus in banana plants.

96 tests100tests1 kit1 mg1000 tests1 mL 96 Tests

Related Pathways

paperclip

#35518307   2020/05/18 To Up

A signal-enhanced and sensitive lateral flow aptasensor for the rapid detection of PDGF-BB.

P
Na Cheng, Yujie Liu, Omar Mukama, Xiaobo Han, Hualin Huang, Shuai Li, Peng Zhou, Xuewen Lu, Zhiyuan Li

1027 related Products with: A signal-enhanced and sensitive lateral flow aptasensor for the rapid detection of PDGF-BB.

100ug Lyophilized100ug Lyophilized50 assays100tests96 tests1 kit100ug Lyophilized100ug Lyophilized400 assays100ug Lyophilized

Related Pathways

    No related Items
paperclip

#32342306   2020/04/27 To Up

Obtaining and Characteristic of Antibodies to Vibrio cholerae Protective Antigens Conjugated with Gold Nanoparticles.

Gold nanoparticle conjugates with Vibrio cholerae antigens were synthesized. The animals were immunized with the obtained conjugates. Rabbit polyclonal antibodies to the antigens were obtained, which showed high specific activity. On the model of white laboratory mice, the protective activity of conjugates of cholera antigens with nanoparticles during infection of vaccinated animals was evaluated using a commercial vaccine as a control. It was shown that in terms of immunogenicity, the created prototypes of cholera vaccine using gold nanoparticles as a carrier and adjuvant complied with the production regulations for the Russian national cholera chemical vaccine.
L A Dykman, O A Volokh, O V Gromova, O S Durakova, S A Vorobeva, M N Kireev, L F Livanova, A K Nikiforov, S Y Shchyogolev, V V Kutyrev

2304 related Products with: Obtaining and Characteristic of Antibodies to Vibrio cholerae Protective Antigens Conjugated with Gold Nanoparticles.

100ug Lyophilized100ug Lyophilized100ug Lyophilized100ug100ug100ug Lyophilized100ug Lyophilized100ug100ug Lyophilized100ug Lyophilized100ug Lyophilized100ug

Related Pathways

paperclip

#32300204   2020/04/16 To Up

Development of a Nanoparticle-based Lateral Flow Strip Biosensor for Visual Detection of Whole Nervous Necrosis Virus Particles.

Effective analysis of pathogens causing human and veterinary diseases demands rapid, specific and sensitive detection methods which can be applied in research laboratory setups and in field for routine diagnosis. Paper lateral flow biosensors (LFBs) have been established as attractive tools for such analytical applications. In the present study a prototype LFB was designed for whole particles (virions) detection of nodavirus or fish nervous necrosis virus. Nodavirus is an important threat in the aquaculture industry, causing severe economic losses and environmental problems. The LFB was based on polyclonal antibodies conjugated on gold nanoparticles for signal visualization. Brain and retinas from fish samples were homogenized, centrifuged and the supernatant was directly applied on the LFB. Formation of a red test line was indicative of nodavirus virions presence. Nodavirus visual detection was completed in short time (30 min). Key factors of the LFB development influencing the assays' detection limit were characterized and the optimum parameters were determined, enabling increased efficiency, excluding non-specific interactions. Therefore, the proposed LFB assay consists a robust, simple, low cost and accurate method for detection of nodavirus virions in fish samples. The proposed biosensor is ideal for development of a commercial kit to be used on aquaculture facilities by fish farmers. It is anticipated that disease monitoring and environmental safety will benefit from the simplification of time consuming and costly procedures.
Dimitra K Toubanaki, Maritsa Margaroni, Athanasios Prapas, Evdokia Karagouni